FJT Power Logo
FJT POWER
Generator Solution Supplier
Zoom In
CUMMINS INDUSTRIAL

160kW 200kVA Cummins Generator Set QSL8.9-G2

100% Factory Tested
Global Warranty
ISO 9001 Certified
Genset Model
TPD220C5
Prime Power(kVA)
200
Engine
QSL8.9-G2
Alternator
N/A
Controller
DSE7320 MKII/DSE8610 MKII
Ideal Power Solution For:
Manufacturing
Data Centers
Mining & Construction
Healthcare
Commercial

Technical Data Sheet

Generator Set Specifications

Specification Technical Data
Product Name 160kW 200kVA Cummins Generator Set QSL8.9-G2
Genset Model TPD220C5/ 160kW Cummins Land Type Diesel Generator
Prime Power (PRP) 160 kW / 200 kVA
Standby Power (ESP) 176 kW / 220 kVA
Engine Model Cummins QSL8.9-G2
Recommended Alternator Stamford UCI274H / Leroy Somer TAL-A42-C
Rated Voltage 400V / 230V (Customizable to 380V, 415V, 440V, 480V)
Rated Frequency 50Hz
Rated Speed 1500 RPM
Rated Current 289 Amps at 400V, 3-phase
Power Factor 0.8 (Lagging)
Phase & Connection 3 Phase, 4 Wire (Y-type connection)
Cooling Method Closed water-cooled radiator system
Starting System 24V DC electric start
Control System Deep Sea DSE7320 MKII
Voltage Regulation AVR automatic voltage regulation, ±1.0%

Engine Specifications

Specification Technical Data
Engine Manufacturer Cummins
Engine Model QSL8.9-G2
Engine Type 6-cylinder in-line, 4-stroke diesel engine
Aspiration Turbocharged and Charge Air Cooled
Displacement 8.9 Liters
Bore × Stroke 114 mm × 145 mm
Compression Ratio 16.6 : 1
Rated Speed 1500 RPM
Gross Engine Output Approx. 196 kWm (Prime Power)
Fuel System High-Pressure Common Rail (HPCR)
Governor Type Electronic governor (ECM)
Cooling System Radiator water-cooled system
Lube Oil Capacity 34.0 Liters
Coolant Capacity Approx. 41 Liters (including radiator)
Fuel Consumption (100% Load) 43.0 Liters/hour
Fuel Consumption (75% Load) 32.0 Liters/hour
Fuel Consumption (50% Load) 22.0 Liters/hour

Alternator Specifications

Specification Technical Data
Alternator Brand Stamford
Recommended Model UCI274H (or equivalent Leroy Somer TAL-A42-C)
Rated Output 200 kVA / 160 kW
Rated Voltage 400V / 230V
Rated Frequency 50Hz
Power Factor 0.8 lagging
Excitation System Brushless, self-excited (PMG optional)
AVR Model AS440 / Equivalent
Voltage Regulation ±1.0%
Insulation Class Class H
Protection Grade IP23
Winding Pitch 2/3 pitch
Bearing Type Single bearing