FJT Power Logo
FJT POWER
Generator Solution Supplier
,

Volvo Engine Generator TAD1345GE TAD1641GE TAD1642GE TWD1643GE Generator Set 360-500KW Genset

Power generation engine range

D16
EU Stage II/Epa Tier 2
  • Excellent load acceptance
  • Highly efficient, belt‐driven coolant pump
  • Piston cooling for low piston temperature
  • Cast‐iron cylinder block
  • Electronic, high‐pressure unit injectors
506–727 kVA
Prime 60hz Electrical Power kVA
461–700 kVA
Prime 50hz Electrical Power kVA
16.1 litres
Displacement litres
VOLVO Technical Parameters(360-500KW)
Genset Model AV400S AV450S AV506S AV550S
Rated Power(KW/KVA) 360/450 400/500 460/575 500/625
Standby Power(KW/KVA) 400/500 450/562 506/632 550/687
Rated Current(A) 649.44 721.6 829.84 902
Weight(kg) 3280 3420
Size(mm) 3400*1160*1890 3500*1160*1890
Diesel
Engine
Model TAD1345GE TAD1641GE TAD1642GE TWD1643GE
Manufacturer VOLVO
Continuous Power(KW) 400 440 513 557
Standby Power(KW) 441 484 565 613
Number of Cylinders 6
Cylinder Diameter*Stroke(mm) 131*150 144*165
Cylinder Arrangement In-line
Compression Ratio 17.5:1
Displacement(L) 12.13 16.12
Intake Type Exhaust gas turbocharger
Cooling Type Tank fan cooling
Rated Speed(rpm) 1500
Fuel Consumption(g/kwh) ≤198
Discharge Temperature(℃) 520
Unpitched Sound(db) 105
Speed Regulation Mechanical speed governors
Alternator Nominal Voltage(V) 400/230
Alternator(Optional) Wandi, Stamford, Engga, Marathon, Elmaer, Leroy-Somer, etc.
Rated Capacity(KW/KVA) 360/450 400/500 460/575 500/625
Rated Power Factor 0.8(lag)
Exciter Type Self Excitation Brushless
Maximum Voltage Adjustment Rate ±1%
Phase Three-phase Four-wire
Control
Panel
Control Cabinet Model TBZK880
Controller(Optional) SmartGen, Deepsea, Comap
Rated Capacity of Circuit Breaker(A) 630A 800A 1000A
Accumulator Rated Capacity(AH) 2×150AH  12V 2×165AH  12V 2×200AH  12V

Overview

The Volvo power generation engine is an in-line 6-cylinder, 16.1-liter diesel genset engine. With electronic high-pressure fuel injection, overhead camshaft, turbo, and air-cooled exhaust manifold.

Implementation Standards

GB/T2820-2009 IDT ISO8528-2005, YD/T502-2007, GB/T20136-2006 ECT.

Optional alternator brand

SmartGen-HGM/Deepsea-DSE/ComAp-CM

The type table is annotated below

  1. Due to limited space, the data listed in this table are the main parameters, detailed parameters please contact us for consultation.
  2. The size and weight vary with the brand of the generator, please contact us for details.
  3. The model may be adjusted at any time, please consult us for the current model first.
  4. “Chongqing FJ Technology Co., LTD” reserves the right of final interpretation of this type table.

Before confirming this configuration

Confirm the required duty, electrical supply, installation interfaces and scope of supply when requesting this product. Unknown requirements can be discussed in the inquiry.

More languages · automatic translation